Menu

HomeHow it worksFor clubsContact UsContact Us

Exercise Heart Rate and DFAa1 Dynamics 24 and 48 h Following Unaccustomed High-Intensity Interval Running: An Exploratory Study of Recovery Responses

Thomas Gronwald, Marcelle Schaffarczyk, Dominik Fohrmann, Billy Sperlich, Olaf Hoos, Peter Düking · Journal of Sports Science and Medicine · 2026

This study tracked heart rate and heart rate variability (measured by DFAa1) in recreationally active people for 24 and 48 hours after an intense running workout to see if these metrics could indicate how well someone is recovering. While muscle strength and subjective stress measures showed clear fatigue signs at both timepoints, the heart rate patterns suggested some recovery processes were underway, though the results were mixed and the researchers emphasized that recovery monitoring needs to look at multiple factors together rather than relying on any single measure.
Takeaway: Use multiple recovery markers—strength, subjective stress, and heart rate responses—rather than any single metric when assessing your readiness after intense training.
Abstract (source)

This study investigates exercise heart rate (HR) and the utility of the short-term scaling exponent alpha1 of Detrended Fluctuation Analysis (DFAa1) within a monitoring battery to assess residual fatigue. In this exploratory repeated-measures study, recreationally active females (n = 11) and males (n = 21) completed four laboratory visits. After one familiarization session and a second baseline visit (PRE), participants completed two unaccustomed high-intensity interval running (HIIT) sessions without a non-HIIT control group, followed by assessments at the third visit (POST24h) and additional follow-up testing at the fourth visit (POST48h). At PRE, POST24h, and POST48h, participants completed a monitoring battery comprising force production (isometric and dynamic strength), recovery-stress scales (ARSS), and a 10-min standardized submaximal cycling bout for assessment of exercise HR and DFAa1, followed by a ramp test to volitional exhaustion. ARSS scales indicated impaired overall recovery (p < 0.001, η2p = 0.53) and increased muscular stress (p < 0.001, η2p = 0.57), accompanied by reduced maximal isometric knee extensor strength (p = 0.001, η2p = 0.20) at POST24h and POST48h. Submaximal testing showed a main effect for HR (p < 0.001, η2p = 0.10), with lower values at POST48h versus PRE. DFAa1 demonstrated reduced values at POST24h (p = 0.003, η2p = 0.08). In the ramp test, HRPEAK was lower at POST48h (p = 0.004, η2p = 0.17). Analysis of HR and DFAa1 kinetics during ramp testing revealed lower HR values (p < 0.05) during the intensity spectrum at POST24h and POST48h, and higher DFAa1 values (p < 0.05) at the beginning of the ramp at POST48h. While neuromuscular performance and subjective recovery-stress responses remained impaired at 48h, the autonomic responses may be compatible with a shift toward recovery, this interpretation remains exploratory given the limited and localized DFAa1 differences. These

Findings: support the need for multidimensional and individualized interpretation of exercise HR and DFAa1 responses when monitoring recovery.

Primary studyOpen accessRecovery & Sleep
Read the original →