Reliability and Validity of AI-Based Pose Estimation Algorithms for Assessing Lower-Limb Flexibility and Joint Range of Motion

Hinata Okuno, Tomoya Ishida, Yuta Koshino, Satoshi Kasahara, Harukazu Tohyama, Mina Samukawa · Sensors · 2026

This study tested whether AI-powered pose estimation software (MediaPipe, OpenPose, and HRNet) can reliably measure lower-limb flexibility and joint range of motion compared to standard manual assessment by a physiotherapist. The AI tools showed good reliability and high correlation with manual measurements in healthy young adults, but they consistently underestimated some movements and had systematic biases, meaning they shouldn't be used interchangeably with traditional methods without accounting for these differences.
Takeaway: Use AI pose estimation as a convenient self-monitoring tool for flexibility tracking, but know that it may systematically underestimate certain measurements compared to manual assessment by a professional.
Abstract (source)

Muscle flexibility and joint range of motion (ROM) evaluation are essential for injury prevention and rehabilitation; however, conventional manual

Methods: are limited in large-scale screening and self-monitoring because of examiner dependency and time constraints. This study evaluated the reliability and validity of AI-based pose estimation for lower-limb flexibility and ROM tests compared with conventional manual measurements. Twenty healthy volunteers (40 lower limbs; age 24.4 ± 2.6 years) underwent three flexibility tests—the Active Knee Extension Test (AKET), Modified Thomas Test (MTT), and Weight-Bearing Lunge Test (WBLT). The tests were assessed by a physiotherapist and three pose-estimation models (MediaPipe, OpenPose, and HRNet). Intra-rater reliability was evaluated with ICC(3,1). Concurrent validity and agreement were assessed using linear regression and Bland–Altman analysis. Intra-rater reliability was good to excellent for all

methods (ICC ≥ 0.87), and concurrent validity was high (r2 ≥ 0.80), except for MTT using the HRNet (r2 = 0.73). Fixed biases were observed during the flexibility test. The limits of agreement ranged from ±8.04–10.87 cm for the AKET and MTT, and ±3.13–4.42 cm for WBLT. The WBLT showed a significant systematic bias, with an underestimation of −6.25° to −7.17° across all models. In young, healthy volunteers under standardized laboratory conditions, pose estimation models showed robust reliability and concurrent validity as

Objective: tools for lower-limb flexibility assessment. However, systematic biases warrant caution regarding the interchangeability between AI-based measurements and conventional

methods.